CLC/TS 50136-9:2013

en: Alarm systems - Alarm transmission systems and equipment - Part 9:Requirements for common protocol for alarm transmission using the Internetprotocol
uk:

TECHNICAL SPECIFICATION SPECIFICATION TECHNIQUE

TECHNISCHE SPEZIFIKATION January 2013
ICS 13.320; 33.040.40
English version
Alarm systems -Alarm transmission systems and equipment -Part 9: Requirements for common protocol for alarm transmission usingthe Internet protocol

Systemes d’alarmes -
Systemes et equipements de transmission d’alarme -
Partie 9 : Exigences pour Ie protocole commun de transmission d’alarme utilisant Ie protocole Internet
Alarmanlagen -
Alarmubertragungsanlagen und - einrichtungen -
Teil 9: Anforderungen an standardisierte Protokolle zur Alarmubertragung unter Nutzung des Internetprotokolls

This Technical Specification was approved by CENELEC on 2012-11-12.
CENELEC members are required to announce the existence of this TS in the same way as for an EN and to make the TS available promptly at national level in an appropriate form. It is permissible to keep conflicting national standards in force.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom.

CENELEC

European Committee for Electrotechnical StandardizationComite Europeen de Normalisation ElectrotechniqueEuropaisches Komitee fur Elektrotechnische Normung
Management Centre: Avenue Mamix 17,

Contents
Foreword 4
1 Scope 5
2 Normative references 5
3 Terms, definitions and abbreviations 5
3.1 Terms and definitions 5
3.2 Abbreviations 5
4 Objective 6
5 Messaging 6
5.1 General 6
5.2 Message format overview 7
5.3 Padding and message length 11
5.4 Hashing 12
5.5 Encryption 12
5.6 Timeouts and retries 13
5.7 Version number 13
5.8 Reverse commands 13
5.9 Initial values 14
6 Message types 14
6.1 General 14
6.2 Path supervision 14
6.3 Event reporting 15
6.4 Configuration messages 19
7 Commissioning and connection setup 27
7 .1 Commissioning 27
12 Connection setup 31
Annex A (normative) Result codes 32
Annex В? (normative) Protocol Identifiers 33
Annex C (normative) Shared secret 34
C.1 Formatting of the shared secret 34
C.2 Checksum for Shared Secret Formatting 34
C.3 Example of Secret Encoding and Formatting 34
Annex D (informative) Examples of messaging sequences 35
D.1 Commissioning 35
D.2 Connection setup 38
Annex E (informative) Examples of application protocols 41

E.1 SIA 41

E.2 Ademco Contact ID 41
E.3 Scancom Fast Format 42
E.4 VdS 2465 42
Annex F (informative) Design principles 44
F.1 General 44
F.2 Information Security 44
F.3 Use of UDP signalling 44
Bibliography 45
Table 1 - Identifiers 7
Table 2- Basic unencrypted format of messages 7
Table 3 - Basic encrypted format of messages 8
Table 4 - Message ID overview 10
Table 5 - Flags 11
Table 6 - Hashing ID’s 12
Table 7 - Encryption ID’s 12
Table 8 - Reverse commands 14
Table 9 - Initial values 14
Table 10- Poll message SPT <- RCT 15
Table 11 - Poll response RCT <- -> SPT 15
Table 12 - Event message format - SPT -> RCT 16
Table 13 - Event message format - Fields 16
Table 14 - Event field 16
Table 15 - Time event field 17
Table 16 - Time message field 17
Table 17 - Link field - IP Address 17
Table 18 - Link field - IP Port number 18
Table 19-Link field-URL 18
Table 20 - Link field - Filename 18
Table 21 - Event response message format 18
Table 22 - Connection handle request message format 19
Table 23 - Connection handle response message format 20
Table 24 - Device ID request message format 20
Table 25 - Device ID request flags 20
Table 26 - Device ID response message format 21
Table 27 - Encryption selection request message format 21
Table 28- ‘Master Encryption Selection request’ flag 21
Table 29 - Encryption selection response message format 22
Table 30 - Encryption key exchange request message format 22
Table 31 - ‘Master Key request’ flag 22
Table 32 - Encryption key exchange response message format 23
Table 33 - Hash selection request message format 23
Table 34 - Hash selection response message format 23
Table 35 - Path supervision request message format 24
Table 36 - Path supervision response message format 24
Table 37 - Set time command message format 24
Table 38 - Set time response message format 25
Table 39 - Protocol version request message format 25
Table 40- Protocol version response message format 25
Table 41 - Transparent message format 25
Table 42 - Transparent response format 26
Table 43 - DTLS completed request message format 26
Table 44 - DTLS completed response message format 26
Table 45 - RCT IP parameter request message format 27
Table 46 - RCT IP parameter response message format 27
Table 47 - Message flow during the commissioning of a new SPT 28
Table 48 - Message flow during connection setup 31
Table A. 1 - Result codes 32
Table B. 1 - Protocol identifiers 33

CLC/TS 50136-9:2013-4-Foreword
This document (CLC/TS 50136-9:2013) has been prepared by CLC/TC 79 "Alarm systems".
Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC [and/or CEN] shall not be held responsible for identifying any or all such patent rights.

1 Scope
This Technical Specification specifies a protocol for point-to-point transmission of alarms and faults, as well as communications monitoring, between a Supervised Premises Transceiver and a Receiving Centre Transceiver using the Internet protocol (IP).
The protocol is intended for use over any network that supports the transmission of IP data. These include Ethernet, xDSL, GPRS, WiFi, UMTS and WIMAX.
The system performance characteristics for alarm transmission are specified in EN 50136-1.
The performance characteristics of the supervised premises equipment should comply with the requirements of its associated alarm system standard and shall apply for transmission of all types of alarms including, but not limited to, fire, intrusion, access control and social alarms.
Compliance with this Technical Specification is voluntary.
2 Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
EN 50136-1:2012, Alarm systems — Alarm transmission systems and equipment — Part 1: General requirements for alarm transmission systems
3 Terms, definitions and abbreviations
3.1 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 50136-1:2012 apply.
3.2 Abbreviations
For the purposes of this document, the following abbreviations apply.
AES Advanced Encryption Standard ARC Alarm Receiving Centre ATS Alarm Transmission System CA X.509 Certificate Authority CBC Cipher Block Chaining CRC Cyclic redundancy check DNS Domain Name System DTLS Datagram Transport Layer Security HL Header Length IP Internet Protocol IV Initialization Vector MAC Media Access Control MTU Maximum Transmission Unit NAT Network Address Translation NIST National Institute of Standards and Technology NTP Network Time Protocol NVM Non-Volatile Memory P-MTU Path Maximum Transmission Unit RCT Receiver Centre Tranceiver
RX Receive
SCTP Stream Control Transmission Protocol
SNTP Simple Network Time Protocol
SPT Supervised Premises Transceiver
TFTP Trivial File Transfer Protocol
TX Transmit
UDP User Datagram Protocol
URI Uniform Resource Identifier
URL Uniform Resource Locator
UTC Coordinated Universal Time
WS Window Size
4 Objective
The object of this Technical Specification is to specify the protocol details (transport and application layers) for alarm transmission systems using Internet Protocol (IP), to ensure interoperability between SPTs and RCTs supplied by different manufacturers. Mechanisms to commission SPT and RCT and build mutual trust between the communicating parties are also described.
As compliance with this Technical Specification is voluntary, any other alarm transmission protocol or equipment not covered by this Technical Specification may be used, provided that the requirements of EN 50136-1 are met.
This protocol is designed to run on top of UDP and is designed to support both IPv4 and IPv6.
NOTE For further discussion of IP and UDP in alarm transmission please see F.3.
5 Messaging
5.1 General
This clause defines the messaging layer, on top of which the alarm event data is transmitted using the existing reporting formats like for example Sia and Contact ID. Clause 7 defines the initial commissioning of an SPT, as well as how SPTs connect to the RCT.
The functionality of the alarm messaging and polling protocol includes:
- exchanging master and session parameters;
(alarm) event reporting (including linking to out-of-band additional data related to events, like audio/video);
- line monitoring;
- transparent message transmission, e.g. vendor specific messages that, for example, can be used for remote commands from RCT to SPT.
It fulfils the following requirements:
- encryption, fulfilling requirements for most demanding category of EN 50136-1;
authentication, fulfilling requirements for most demanding category of EN 50136-1;
- SPT: allows a broad range of hardware (limited demands on memory footprint as well as CPU power);
RCT: allows support for at least 10 000 SPTs in compliance with any category in EN 50136-1, using modern general purpose server hardware;
- allow Dynamic IP addresses of the SPTs;
allow one or more SPTs to be placed

Схожі документи

ДСТУ HD 604 S1:2012 0,6/1 kV and 1,9/3,3 kV power cables with special fire performance for use in power stations ДСТУ HD 604 S1:2012 Кабелі електроживлення на напругу 0,6/1 кВ і 1,9/3,3 кВ зі спеціальними протипожежними характеристиками для застосування на електростанціях ДСТУ IEC 60061-3:2005 Цоколі та патрони лампові разом з калібрами для перевірки їх взаємозамінності та безпечності. Частина 3. Калібри ДСТУ Б Д.2.2-15:2012 Ресурсні елементні кошторисні норми на будівельні роботи. Оздоблювальні роботи (Збірник 15) ДСТУ-Н Б EN 1999-1-1:2010 Єврокод 9. Проектування алюмінієвих конструкцій. Частина 1-1. Загальні правила для конструкцій / Eurocode 9. Design of aluminium structures. Part 1-1. General structural rules ДСТУ 2767-94 Керівництво з навантаження силових сухих трансформаторів / Руководство по нагрузке силовых сухих трансформаторов ДСТУ Б Д.2.4-15:2014 (Збірник 15). Ресурсні елементні кошторисні норми на ремонтно-будівельні роботи. Внутрішні санітарно-технічні роботи ДСТУ-Н Б EN 1999-1-1:2010 Єврокод 9. Проектування алюмінієвих конструкцій. Частина 1-1. Загальні правила для конструкцій